Home / Products / DM Plant (Two Bed De-ionizer)
Cation bedH⁺ exchangeAnion bedOH⁻ exchangeAcidic waterRaw waterPureDM waterCations are swapped for H⁺, then anions for OH⁻: salt-free water
Where the DM plant sitsRawwaterSand / carbonfilterCation +anion bedsArukalDMwaterCation and anion beds remove nearly all dissolved salts
DM plant capacity (m³/h)1DM 1lab, small boiler5DM 5small industry10DM 10process25DM 25power50DM 50largem³/hCapacity is for typical raw water TDS of 300 – 500 mg/L

Swipe a diagram sideways to see all of it

Plants and systems

DM Plant (Two Bed De-ionizer)

Demineralised water from cation and anion exchange beds

Boiler feedProcess waterTwo bedAutomatic

Two bed de-ionizer plants for boiler feed, process and laboratory water. Select, supply and support from Arukal Instruments, serving India and Nepal.

< 20 µS/cmOutlet conductivity
0.5 – 50 m³/hCapacity
< 0.2 mg/LSilica
Cation + anionBeds
Overview

What it does

A DM plant removes dissolved salts from water. In a two bed de-ionizer the water first passes through a cation bed that swaps metal ions for hydrogen, then an anion bed that swaps acids for hydroxide. The result is demineralised water with very low conductivity.

Arukal designs and supplies DM plants from small skids to large installations, with FRP or MS rubber-lined vessels, valves, regeneration tanks and controls. We also supply the resin and support regeneration and operation.

Where the DM plant sitsRawwaterSand / carbonfilterCation +anion bedsArukalDMwaterCation and anion beds remove nearly all dissolved salts
1

Cation exchange

Cation resin removes calcium, magnesium and sodium and releases hydrogen ions.

2

Anion exchange

Anion resin removes chloride, sulphate, bicarbonate and silica and releases hydroxide.

3

DM water out

Hydrogen and hydroxide combine to form pure water with very low conductivity.

4

Regeneration

Acid restores the cation bed and alkali restores the anion bed when capacity is used up.

Features & benefits

Why choose Arukal DM plants

Low conductivity

Typical outlet below 20 µS/cm with a two bed plant.

Wide capacity range

Small skids up to large industrial plants.

Automatic or manual

Valve-operated or PLC-controlled regeneration.

Right materials

FRP or MS rubber-lined vessels, acid and alkali tanks, dosing and pipework.

Resin and spares

Fresh resin charge and spares from one supplier.

Design and support

We design from your water analysis and support start-up.

Technical data

Specifications

Typical values. Values are typical for the product family and given for guidance. Exact figures depend on the make and model supplied; ask us for the data sheet of the specific model.

Plant (typical)

ProcessStrong acid cation + strong base anion (two bed), optional degasser
Capacity0.5 – 50 m³/h (larger on request)
Outlet conductivity< 20 µS/cm (typical)
Outlet silica< 0.2 mg/L (typical)
Outlet pH6.5 – 8.5 (typical)
Service flow rateapprox. 20 – 30 m/h per bed
RegenerantsHCl or H₂SO₄ for cation; NaOH for anion

Construction

VesselsFRP, or MS rubber lined
ValvesDiaphragm, butterfly or multiport
PipingUPVC / CPVC / MS rubber lined
ControlsManual, semi-automatic or PLC with conductivity monitoring
Models

Typical plant sizes

ModelCapacityTypical vesselTypical use
DM 11 m³/h18 – 24 inLaboratory, small boiler
DM 55 m³/h36 inSmall industry, boiler feed
DM 1010 m³/h48 inProcess and boiler feed
DM 2525 m³/h72 inPower and process plants
DM 5050 m³/h96 in and aboveLarge industry

Capacity is for a typical raw water TDS of 300 – 500 mg/L. Higher TDS reduces output per cycle.

DM plant capacity (m³/h)1DM 1lab, small boiler5DM 5small industry10DM 10process25DM 25power50DM 50largem³/hCapacity is for typical raw water TDS of 300 – 500 mg/L
Selection guide

What we need to design your DM plant

  • Raw water analysis (TDS, hardness, alkalinity, chloride, sulphate, silica)
  • Required capacity (m³/h or m³/day) and hours of operation
  • Required outlet conductivity and silica
  • Acid and alkali available, and the drain arrangement
Choosing by waterHardnessonlyboiler feed,low TDSSoftenerplantLow-pressureboilerTDS below1,000Two bed DMHigh purityvery lowconductivityDM + mixedbedHigh TDSabove 1,000mg/LRO then DMSend us your water analysis for a firm recommendation
Applications

Where it is used

Boiler feed water
Process water
Pharma and laboratory water
Power plants
Battery and chemical plants
Cooling make-up
Handling & care

Installation, use and care

  1. 1

    Commission

    Rinse the new resin, set regeneration levels and record the outlet conductivity.

  2. 2

    Operate

    Run each bed until the outlet conductivity or silica rises, then regenerate.

  3. 3

    Regenerate

    Use the correct acid and alkali strength and contact time. Never under-regenerate.

  4. 4

    Maintain

    Check valves, tanks and instruments, and test resin capacity once a year.

Downloads

Data sheet and brochure

FAQ

Frequently asked questions

What is the difference between DM and softener?

A softener only removes hardness. A DM plant removes almost all dissolved salts.

Do I need a degasser?

A degasser removes carbon dioxide before the anion bed, which saves alkali when the water is high in bicarbonate.

When should I choose a mixed bed instead?

Use a mixed bed as a polisher after the two bed plant when you need very low conductivity.

How often will it regenerate?

It depends on raw water TDS and capacity. Typical cycles are 8 to 24 hours.

Can you supply replacement resin?

Yes. See Ion Exchange Resin.