📞 +91-8538070869✉ info@arukalinstruments.in
Sales & service: West Bengal • Guwahati, Assam
Home / Products / UF Plant
FeedFiltrate (clean water)Hollow fibres0.01 – 0.04 µm poresSolids stay outsideWater passes through the fibre wall; solids and bacteria cannot
Where the UF plant sitsRawwaterSandfilterUFplantArukalROmembranesTreatedwaterUF gives clear, low-SDI water that protects the RO
UF skid capacity (m³/h)1UF 1drinking5UF 5commercial10UF 10RO feed25UF 25industry50UF 50reusem³/hMore modules are added as the flow grows

Swipe a diagram sideways to see all of it

Plants and systems

UF Plant

Ultrafiltration plants for clear, low-turbidity water

Pre-treatmentDrinking waterReuseHollow fibre

Hollow-fibre ultrafiltration for pre-treatment, drinking water and reuse. Select, supply and support from Arukal Instruments, serving India and Nepal.

0.01 – 0.04 µmPore size
< 0.1 NTUFiltrate turbidity
1 – 100 m³/hCapacity
up to 95 %Recovery
Overview

What it does

Ultrafiltration (UF) uses thousands of hollow fibres with tiny pores to remove suspended solids, bacteria and many viruses. It gives clear water with steady quality, even when the raw water changes.

A UF plant is often used ahead of RO to protect the membranes, or to make safe drinking water and reuse water from treated sewage. Arukal supplies UF skids with modules, pumps, valves, backwash and cleaning systems and controls.

Where the UF plant sitsRawwaterSandfilterUFplantArukalROmembranesTreatedwaterUF gives clear, low-SDI water that protects the RO
1

Feed

Pre-filtered water is pumped to the UF module.

2

Filtration

Water passes through the pores of the hollow fibres from outside to inside, or inside to outside. Solids and bacteria stay behind.

3

Filtrate

Clean water collects and goes to the filtrate tank.

4

Backwash and CEB

Regular backwash and chemical enhanced backwash clear the fibres.

Features & benefits

Why choose Arukal UF plants

Consistent clear water

Turbidity below 0.1 NTU whatever the raw water.

Bacteria barrier

Pores far smaller than bacteria give a dependable barrier.

Protects RO

Keeps SDI low, which extends membrane life.

Automatic cleaning

Timer-controlled backwash and chemical cleaning.

Small footprint

Compact skids compared with sand and media filters.

Support

Design, commissioning and service from Arukal.

Technical data

Specifications

Typical values. Values are typical for the product family and given for guidance. Exact figures depend on the make and model supplied; ask us for the data sheet of the specific model.

Plant (typical)

Membrane typeHollow fibre, PVDF / PES / PAN
Nominal pore size0.01 – 0.04 µm
Design fluxapprox. 40 – 80 L/m²/h (LMH)
Operating pressure (TMP)0.2 – 1.5 bar, up to 2.1 bar max
Filtrate qualityTurbidity < 0.1 NTU, SDI < 2 (typical)
Recovery90 – 95 %
BackwashEvery 30 – 60 minutes, 30 – 60 seconds

Skid

Feed water limitsTurbidity up to 50 NTU, TSS below 50 mg/L (with strainer)
Strainer100 – 200 micron
MaterialsUPVC / SS 304 / FRP module housing
ControlsPLC with automatic backwash and CEB
Models

Typical skid sizes

ModelCapacityModulesTypical use
UF 11 m³/h1 small moduleDrinking water, small site
UF 55 m³/h2 – 4 modulesCommercial, institutional
UF 1010 m³/h4 – 8 modulesRO pre-treatment
UF 2525 m³/h10 – 14 modulesIndustrial plants
UF 5050 m³/h20+ modulesReuse and large plants

Capacity depends on water quality and design flux. Ask us for a design.

UF skid capacity (m³/h)1UF 1drinking5UF 5commercial10UF 10RO feed25UF 25industry50UF 50reusem³/hMore modules are added as the flow grows
Selection guide

What we need to design your UF plant

  • Source of water (borewell, river, treated sewage) and analysis (turbidity, TSS, iron, COD)
  • Required filtrate flow (m³/h) and hours of operation
  • What the filtrate will be used for (RO feed, drinking, reuse)
  • Chemicals and power available
Choosing by dutyRO feedprotect themembraneUF before RODrinkingwaterbacteriabarrierUF +disinfectionSewage reuseafter STPUF + RODirty sourcehigh turbidityClarifier +UFSend us your water analysis for a firm recommendation
Applications

Where it is used

RO pre-treatment
Drinking water plants
Treated sewage reuse
Process water
Swimming pools
Surface and river water
Handling & care

Installation, use and care

  1. 1

    Pre-filter

    Always fit a strainer ahead of the UF so the fibres are not clogged by coarse particles.

  2. 2

    Backwash

    Keep backwash timers and flows as designed. Do not skip cycles.

  3. 3

    Clean

    Run CEB and, when needed, a full chemical clean. Use chemicals approved for the membrane.

  4. 4

    Check

    Track TMP and filtrate flow to know when cleaning is due.

Downloads

Data sheet and brochure

FAQ

Frequently asked questions

UF or sand filter before RO?

UF gives much lower SDI and steadier water, so RO membranes foul less. Sand filters cost less but protect less.

Does UF remove salts?

No. It removes solids, bacteria and many viruses, but dissolved salts pass through.

How long do UF modules last?

Often 3 to 7 years, depending on feed water and cleaning.

What about chlorine?

PVDF and PES fibres tolerate chlorine within limits. Check the module datasheet.

Can UF replace disinfection?

It is a strong barrier, but many sites add chlorine or UV for residual protection.

Related products

Supplied across India — enquire from Guwahati, Assam & North-East, West Bengal or anywhere in India and Nepal.

Need help choosing the right water treatment solution?

Request a Quote →