📞 +91-8538070869✉ info@arukalinstruments.in
Sales & service: West Bengal • Guwahati, Assam
Home / Products / Iron Removal Plant
Aerated wateroxidises ironIron removal mediacatalyticSupport gravel3 – 40 mmFeed inOutletOxidised iron is trapped by the media, then backwashed out
Where the iron removal plant sitsBorewellwaterAerationIron removalfilterArukalClearwaterOxidise the iron, then filter it out
Iron removal plant sizesIR 11 m³/hIR 55 m³/hIR 1010 m³/hIR 2525 m³/hMedia volume depends on iron level and flow

Swipe a diagram sideways to see all of it

Plants and systems

Iron Removal Plant

Remove dissolved iron from borewell and groundwater

Borewell waterAerationOxidationStain removal

Clear, stain-free water by oxidising and filtering out iron. Select, supply and support from Arukal Instruments, serving India and Nepal.

< 0.3 mg/LOutlet iron
0.5 – 100 m³/hCapacity
Aerate + filterMethod
Iron removal mediaMedia
Overview

What it does

Many borewells give water with dissolved iron. It looks clear at first, then turns brown on standing, stains clothes, taps and tanks, and gives a metallic taste. An iron removal plant oxidises the iron and filters it out.

Arukal supplies iron removal plants with aeration or chemical oxidation, contact time and filters with special media. We also supply filter media for existing iron removal filters and advise on backwash.

Where the iron removal plant sitsBorewellwaterAerationIron removalfilterArukalClearwaterOxidise the iron, then filter it out
1

Oxidation

Aeration or a dose of chlorine or permanganate converts dissolved iron into solid particles.

2

Contact

A short contact time lets the iron particles grow.

3

Filtration

A media filter traps the iron, giving clear water.

4

Backwash

Regular backwash flushes the iron from the bed to drain.

Features & benefits

Why choose Arukal iron removal plants

Removes iron and stains

Clear water without rust stains or metallic taste.

Chemical-free option

Aeration alone suits many borewell waters.

Special media

Catalytic media oxidise and filter iron in one bed.

Automatic backwash

Timer or flow-based backwash valves.

Sized to your water

Designed from iron, pH and flow.

Support and media

Replacement media and servicing.

Technical data

Specifications

Typical values. Values are typical for the product family and given for guidance. Exact figures depend on the make and model supplied; ask us for the data sheet of the specific model.

Plant (typical)

Feed ironup to 10 – 20 mg/L (higher on request)
Outlet iron< 0.3 mg/L (typical, to drinking water norms)
Feed pH6.5 – 8.5 (higher pH helps oxidation)
Filtration velocityapprox. 8 – 12 m/h
Backwash rateapprox. 25 – 30 m/h, 10 – 15 minutes
Capacity0.5 – 100 m³/h

Construction

AeratorSpray, cascade or air-injection (venturi / blower)
VesselMS epoxy-coated, rubber lined, or FRP
MediaIron removal media on gravel support
ValvesMultiport or diaphragm valves, manual or automatic
Models

Typical plant sizes

ModelCapacityVesselTypical use
IR 11 m³/h18 – 24 inHome, small shop
IR 55 m³/h36 inHotel, school, small industry
IR 1010 m³/h48 inIndustry, society
IR 2525 m³/h72 inMunicipal and industrial

Capacity and media volume depend on feed iron and pH. Ask us for a design.

Iron removal plant sizesIR 11 m³/hIR 55 m³/hIR 1010 m³/hIR 2525 m³/hMedia volume depends on iron level and flow
Selection guide

What we need to design your iron removal plant

  • Water analysis (iron, manganese, pH, alkalinity, hardness, turbidity)
  • Required flow (m³/h) and daily demand
  • Whether chemicals can be used
  • Existing tank and pump arrangement
Choosing by iron levelBelow 2 mg/Llight ironAerate + sandfilter2 – 10 mg/LtypicalborewellAerate + ironmediaAbove 10mg/Lheavy ironChemicaloxidationIron +manganeseboth presentMGS mediaplantSend us your water analysis for a firm recommendation
Applications

Where it is used

Borewell water
Hostels and hotels
Housing societies
Industries
Pre-treatment before RO
Drinking water plants
Handling & care

Installation, use and care

  1. 1

    Aerate

    Keep the aerator clean and the air supply working so oxidation stays effective.

  2. 2

    Backwash

    Backwash on time. Low backwash lets iron build up and the media cake.

  3. 3

    Test

    Test outlet iron weekly. A rise means the media needs attention.

  4. 4

    Replace media

    Top up or replace media when it loses capacity.

Downloads

Data sheet and brochure

FAQ

Frequently asked questions

Why does my water turn brown after standing?

Dissolved iron oxidises in air and turns into rust-coloured particles.

Do I need chemicals?

Not always. Aeration alone works on many waters. High iron or organic iron may need chlorine or permanganate.

Can the same plant remove manganese?

Partly. Manganese needs a stronger oxidant or a special media. See Manganese Removal Plant.

How often should I backwash?

Typically every 1 to 3 days, depending on iron and flow.

Do you supply media for my old filter?

Yes. See Filter Media.

Related products

Supplied across India — enquire from Guwahati, Assam & North-East, West Bengal or anywhere in India and Nepal.

Need help choosing the right water treatment solution?

Request a Quote →