Water Treatment Chemicals
CHEMICALTANKMetering pumpTreated water lineInjection pointChemical drumDose in proportion to flowTypical dose rate2 – 5 mg/L
Where the chemical dosing sitsRawwaterChemicaldosingArukalFiltrationROmembranesDosing points change with the plant and the problem
Typical pack sizes5 kg can25 kg drum50 kg drumBagdry productsAntiscalants · cleaners · biocides · boiler, cooling and effluent chemicals

Swipe a diagram sideways to see all of it

Industrial water treatment

Water Treatment Chemicals

Antiscalants, cleaners, biocides and boiler, cooling and effluent chemicals

AntiscalantRO cleanersBiocideCoagulant

Chemicals that protect membranes, boilers, cooling systems and effluent plants. Select, supply and support from Arukal Instruments, serving India and Nepal.

Antiscalant · CleanersRO programme
Scale · Corrosion · BiocideBoiler and cooling
Coagulant · FlocculantEffluent
5 · 25 · 50 kgPack sizes
Overview

What it does

The right chemical in the right dose protects equipment and saves energy. Antiscalants stop salts from scaling RO membranes; cleaners restore them; boiler and cooling chemicals control scale, corrosion and growth; coagulants and flocculants clear effluent and turbid water.

Arukal supplies a full range and helps you choose the product and dose for your water. Our Online Consultation Service can review your plant data and help you set up a dosing programme.

Where the chemical dosing sitsRawwaterChemicaldosingArukalFiltrationROmembranesDosing points change with the plant and the problem
1

Know your water

Water analysis shows scaling, corrosion and fouling risk.

2

Select the product

We match the chemical to the problem and the equipment.

3

Dose correctly

Dosing pumps meter the chemical in proportion to flow.

4

Check and adjust

Test results and plant data tell us when to change the dose.

Product range

What we supply

Water treatment chemicals

Antiscalant Chemical

Stops scale forming on RO and NF membranes.

SMBS Chemical

Sodium metabisulphite for dechlorination and membrane preservation.

Membrane Cleaning Chemical

Acid and alkaline cleaners for RO and NF membranes.

Chlorine

Disinfection of drinking, process and cooling water.

Coagulation & Flocculation

Coagulants and flocculants for clarifying and effluent treatment.

Alum

Aluminium sulphate coagulant for turbidity and colour removal.

Lime

pH correction and softening, and for effluent treatment.

Soda

Soda ash for pH correction and softening.

Boiler chemicals

Boiler Descaling Chemical

Removes scale from boiler tubes and heat surfaces.

Boiler Antiscalant

Keeps hardness and silica from forming scale inside the boiler.

Oxygen Scavenger

Removes dissolved oxygen from boiler feed water to stop corrosion.

Cooling tower chemicals

Biocide Chemical

Controls bacteria, algae and slime in cooling towers.

Ask us for grades, packs and prices. Request a quote

Features & benefits

Why choose Arukal water treatment chemicals

Full range

Antiscalants, cleaners, biocides, coagulants, flocculants, pH correctors and boiler chemicals.

Protects equipment

Stops scale, corrosion and biofouling in membranes, boilers and cooling towers.

Dosing guidance

Dose rate and pump selection support for your plant.

Saves energy

Clean membranes and tubes need less pressure and heat.

Compliance support

Chemicals for effluent and sewage treatment to meet discharge limits.

Safe packing

Labelled packs with safety data on request.

Technical data

Specifications

Typical values. Values are typical for the product family and given for guidance. Exact figures depend on the make and model supplied; ask us for the data sheet of the specific model.

RO chemicals (typical)

Antiscalant doseapprox. 2 – 5 mg/L in feed (depends on water)
Low pH cleanerCitric or acid based, for scale and metal oxides
High pH cleanerAlkaline with surfactant, for organics and biofilm
Biocide for RONon-oxidising, membrane safe

Boiler and cooling (typical)

Boiler programmeOxygen scavenger, scale and sludge conditioner, pH booster
Cooling programmeScale and corrosion inhibitor, biocide (oxidising and non-oxidising)

Effluent and sewage (typical)

CoagulantPAC, alum, ferric chloride
FlocculantAnionic, cationic or non-ionic polymer
pH correctionCaustic soda, hydrochloric acid, lime
Product range

Chemical groups and use

GroupExamplesUsed inTypical pack
AntiscalantsLiquid RO antiscalantsRO plants25 kg
Membrane cleanersLow pH and high pH cleanersRO cleaning25 kg
Boiler chemicalsOxygen scavenger, scale controlBoilers25 / 50 kg
Cooling chemicalsInhibitors and biocidesCooling towers25 / 50 kg
Coagulants and flocculantsPAC, alum, polymersETP, STP, clarifiers25 / 50 kg

Brand and grade as available. Safety data sheets and dose guidance on request.

Typical pack sizes5 kg can25 kg drum50 kg drumBagdry productsAntiscalants · cleaners · biocides · boiler, cooling and effluent chemicals
Selection guide

What we need to recommend the right chemical

  • Where it will be used (RO, boiler, cooling tower, ETP, STP)
  • Water analysis, or the effluent quality
  • Flow rate and operating conditions
  • Current chemical and dose, if any
Choosing by systemRO plantscale andfoulingAntiscalant +cleanersBoilerfeed and steamScavenger +scale controlCoolingtowerscale, rust,growthInhibitor +biocideETP / STPclarifyeffluentCoagulant +polymerSend us your plant details for a firm recommendation
Applications

Where it is used

RO plants
Boilers and cooling towers
Effluent treatment
Sewage treatment plants
Clarifiers and filters
pH correction
Handling & care

Installation, use and care

  1. 1

    Handle

    Wear gloves and goggles. Read the label and safety data sheet before use.

  2. 2

    Store

    Keep chemicals in sealed original packs, cool and away from acids or oxidisers.

  3. 3

    Dose

    Use a calibrated dosing pump and never mix different chemicals in one tank.

  4. 4

    Record

    Log consumption and test results so dosing can be tuned.

Downloads

Data sheet and brochure

FAQ

Frequently asked questions

How much antiscalant should I dose?

The dose depends on feed water and recovery. We calculate it from your analysis.

Can I use any cleaner on my membrane?

No. Use cleaners that are safe for your membrane type and follow the pH and temperature limits.

Do you supply dosing pumps?

We can advise on dosing pumps and tanks together with the chemical.

Can you help with effluent chemicals?

Yes. Send the effluent details and we will suggest the coagulant and polymer.

Is a safety data sheet available?

Yes, on request for each product.

Related products

Supplied across India — enquire from Guwahati, Assam & North-East, West Bengal or anywhere in India and Nepal.

Need help choosing the right water treatment solution?

Request a Quote →