📞 +91-8538070869✉ info@arukalinstruments.in
Sales & service: West Bengal • Guwahati, Assam
Home / Products / Manganese Removal Plant
Oxidant dosedKMnO₄ or chlorineManganese greensandcatalyticSupport gravel3 – 40 mmFeed inOutletCatalytic media oxidises and traps manganese
Where the manganese removal plant sitsBorewellwaterOxidantdosingManganesefilterArukalClearwaterOxidant dosing and catalytic media remove manganese
Manganese removal plant sizesMR 11 m³/hMR 55 m³/hMR 1010 m³/hMR 2525 m³/hDesigned from manganese, iron and pH

Swipe a diagram sideways to see all of it

Plants and systems

Manganese Removal Plant

Remove manganese from groundwater with oxidation and catalytic media

GroundwaterCatalytic mediaKMnOâ‚„Black stains

Stop black staining and bitter taste caused by dissolved manganese. Select, supply and support from Arukal Instruments, serving India and Nepal.

< 0.1 mg/LOutlet manganese
0.5 – 100 m³/hCapacity
Permanganate / chlorineOxidant
Catalytic MGSMedia
Overview

What it does

Manganese in borewell water leaves black stains on fixtures and laundry, and gives a metallic taste. It is harder to remove than iron because it oxidises more slowly and at higher pH.

Arukal supplies manganese removal plants that dose an oxidant such as potassium permanganate or chlorine and filter the water through catalytic media. We also supply the media and advise on regeneration.

Where the manganese removal plant sitsBorewellwaterOxidantdosingManganesefilterArukalClearwaterOxidant dosing and catalytic media remove manganese
1

Raise pH if needed

Manganese oxidises faster at higher pH, so pH may be corrected first.

2

Oxidant dose

Potassium permanganate or chlorine oxidises dissolved manganese into solids.

3

Catalytic filtration

Manganese greensand or similar media catalyses oxidation and traps the particles.

4

Backwash and regenerate

Backwash clears the solids; the media is regenerated with permanganate if it is a greensand type.

Features & benefits

Why choose Arukal manganese removal plants

Removes manganese

Outlet manganese below 0.1 mg/L is typical.

Also handles iron

The same plant removes iron and, with the right media, hydrogen sulphide.

Catalytic media

Media that speeds up oxidation for better removal.

Dosing included

Dosing pump, tank and controls in the scope.

Sized to your water

Designed from manganese, iron and pH.

Support

Start-up, media and servicing.

Technical data

Specifications

Typical values. Values are typical for the product family and given for guidance. Exact figures depend on the make and model supplied; ask us for the data sheet of the specific model.

Plant (typical)

Feed manganeseup to 2 – 5 mg/L (higher on request)
Outlet manganese< 0.1 mg/L (typical)
Feed pH6.8 – 8.5 (pH correction if lower)
Filtration velocityapprox. 6 – 10 m/h
Backwash rateapprox. 25 – 30 m/h
OxidantKMnOâ‚„ (approx. 1 mg/L per 0.5 mg/L Mn + 0.2 mg/L per mg Fe), or chlorine

Construction

VesselMS rubber lined or epoxy-coated, or FRP
MediaManganese greensand, pyrolusite or equivalent on gravel support
DosingDosing pump with chemical tank and mixer
ValvesMultiport or diaphragm valves
Models

Typical plant sizes

ModelCapacityVesselTypical use
MR 11 m³/h18 – 24 inHome, small shop
MR 55 m³/h36 inHotel, institution
MR 1010 m³/h48 inIndustry, society
MR 2525 m³/h72 inMunicipal and industrial

Plants are designed from the analysis of manganese, iron, pH and organics.

Manganese removal plant sizesMR 11 m³/hMR 55 m³/hMR 1010 m³/hMR 2525 m³/hDesigned from manganese, iron and pH
Selection guide

What we need to design your manganese removal plant

  • Water analysis (manganese, iron, pH, alkalinity, hardness, hydrogen sulphide)
  • Required flow (m³/h) and daily demand
  • Whether permanganate or chlorine can be handled
  • Existing pump, tank and space
Choosing by waterLow Mn, pHabove 7light loadCatalyticmediaMn + irontypicalborewellOxidant + MGSmediaLow pHbelow 6.8pH correctionfirstSulphidesmellHâ‚‚S presentAeration +oxidantSend us your water analysis for a firm recommendation
Applications

Where it is used

Borewell water
Hostels and hotels
Housing societies
Industries
Municipal wells
Pre-treatment before RO
Handling & care

Installation, use and care

  1. 1

    Dose

    Keep the oxidant dose steady and tuned to the analysis. Over-dosing leaves a pink tint.

  2. 2

    Backwash

    Backwash on time so the media does not cake.

  3. 3

    Regenerate

    Regenerate greensand media with permanganate as advised.

  4. 4

    Test

    Check outlet manganese weekly and adjust.

Downloads

Data sheet and brochure

FAQ

Frequently asked questions

Why is manganese harder to remove than iron?

It oxidises slowly and needs a stronger oxidant or higher pH.

Do I need permanganate?

For many waters yes, or chlorine with catalytic media. We select from your analysis.

Is manganese harmful?

It causes staining and taste, and drinking water standards limit it. Ask us about the limit that applies to you.

Can this plant also remove iron?

Yes. Iron is removed in the same bed.

Is regeneration needed?

Some media need periodic regeneration, others do not. We advise by media.

Related products

Supplied across India — enquire from Guwahati, Assam & North-East, West Bengal or anywhere in India and Nepal.

Need help choosing the right water treatment solution?

Request a Quote →