📞 +91-8538070869✉ info@arukalinstruments.in
Sales & service: West Bengal • Guwahati, Assam
Home / Products / UV Disinfection System
Water inSafe waterUV-C lamp, 254 nmQuartz sleeveControl panel, ballastSS 304 / 316 chamberUVLight at 254 nm breaks the DNA of bacteria and viruses
Where the UV disinfection system sitsRawwaterFiltersUVchamberArukalStorage /useThe final barrier: safe water without chemicals
UV system flow (m³/h)1UV 1home5UV 5institution10UV 10plant25UV 25industry50UV 50largem³/hFlow is at about 90 % UV transmittance

Swipe a diagram sideways to see all of it

Plants and systems

UV Disinfection System

Chemical-free disinfection with ultraviolet light

Drinking waterReuse waterChemical freeStainless steel

Inactivate bacteria and viruses without adding chemicals or changing taste. Select, supply and support from Arukal Instruments, serving India and Nepal.

254 nmWavelength
30 – 40 mJ/cm²UV dose
up to 99.99 %Bacteria kill
0.5 – 100 m³/hCapacity
Overview

What it does

A UV disinfection system passes water through a chamber with a UV-C lamp inside a quartz sleeve. The light damages the DNA of bacteria, viruses and cysts so that they cannot multiply, without adding chemicals or changing taste, colour or smell.

Arukal supplies UV systems in stainless steel chambers with quartz sleeves, UV lamps, ballasts and control panels, sized to the flow and the water quality. We also supply replacement lamps and sleeves.

Where the UV disinfection system sitsRawwaterFiltersUVchamberArukalStorage /useThe final barrier: safe water without chemicals
1

Water enters the chamber

Pre-filtered water flows through a stainless steel chamber.

2

UV exposure

The UV-C lamp, inside a quartz sleeve, exposes the water to 254 nm light.

3

Microbes inactivated

The dose damages microbial DNA so organisms cannot multiply.

4

Safe water out

Disinfected water leaves for storage or use.

Features & benefits

Why choose Arukal UV disinfection systems

No chemicals

No chlorine taste, smell or by-products.

Fast and effective

Disinfects as the water passes, with no contact tank.

Wide capacity range

From small units to large plants.

Stainless steel chamber

SS 304 or 316 for long life.

Lamp monitoring

UV intensity sensor and lamp-hours alarm available.

Lamps and sleeves

Replacement lamps, sleeves and ballasts from Arukal.

Technical data

Specifications

Typical values. Values are typical for the product family and given for guidance. Exact figures depend on the make and model supplied; ask us for the data sheet of the specific model.

System (typical)

Lamp typeLow-pressure UV-C, 254 nm
UV dose30 – 40 mJ/cm² at end of lamp life
Microbial reductionup to 99.99 % (4 log) bacteria
Feed UV transmittance (UVT)> 75 % (higher is better)
Lamp lifeapprox. 9,000 – 12,000 hours (about 1 year)
Power230 V single phase (larger systems three phase)

Construction

ChamberSS 304 or SS 316
SleeveHigh-purity quartz
ControlsBallast, lamp indicator, optional UV sensor and flow switch
ConnectionsFlanged or threaded
Models

Typical system sizes

ModelFlowLampsTypical use
UV 11 m³/h1 × 25 WHomes, small commercial
UV 55 m³/h1 × 80 WInstitutions, small plant
UV 1010 m³/h2 × 80 WPlants, bottling lines
UV 2525 m³/h4 × 80 WIndustry, municipal
UV 5050 m³/h8 × 80 WLarge plants

Flow is at a typical UVT of 90 % and a dose of 30 mJ/cm². Lower UVT needs a larger unit.

UV system flow (m³/h)1UV 1home5UV 5institution10UV 10plant25UV 25industry50UV 50largem³/hFlow is at about 90 % UV transmittance
Selection guide

What we need to size your UV system

  • Water flow rate (m³/h) and operating pressure
  • Water source and UV transmittance, or a water analysis
  • Required dose or standard to meet
  • Power supply and space
Choosing by dutyHome, shopsmall flowUV 1Institutionmoderate flowUV 5 – 10Plant,bottlingcontinuousUV 10 – 25Large sitehigh flowUV 50 andaboveSend us your flow and water quality for a firm recommendation
Applications

Where it is used

Drinking water plants
Bottled water lines
Treated sewage reuse
Food and beverage
Hospitals and hotels
Pharma and process water
Handling & care

Installation, use and care

  1. 1

    Pre-filter

    Filter the water first. Turbidity and iron shield microbes from the light.

  2. 2

    Replace lamps

    Replace lamps at the rated hours even if they still glow; the UV output has dropped.

  3. 3

    Clean the sleeve

    Clean the quartz sleeve regularly, because scale and dirt reduce the dose.

  4. 4

    Warm up

    Let the lamp warm up before use, and do not run it with no water flow.

Downloads

Data sheet and brochure

FAQ

Frequently asked questions

Does UV leave a residual?

No. UV disinfects only as water passes. If water is stored or piped far, add chlorine for residual protection.

Does UV change taste or smell?

No. It adds nothing to the water.

Why does water need pre-filtration?

Turbidity, colour and iron block UV light, so microbes escape the dose.

How often should lamps be changed?

Around once a year, or at the rated hours.

Can UV remove chemicals?

No. It only inactivates microbes.

Related products

Supplied across India — enquire from Guwahati, Assam & North-East, West Bengal or anywhere in India and Nepal.

Need help choosing the right water treatment solution?

Request a Quote →