An RO plant rarely fails without warning. Pressure, flow and permeate quality drift first. If those numbers are written down every shift, the drift is visible and the fix is usually cheap. This checklist shows what to record and when to act.
| Reading | Why it matters |
|---|---|
| Feed, interstage and reject pressure | Rising pressure drop across a stage points to fouling or scaling |
| Permeate and reject flow | Falling permeate flow at the same pressure points to fouling |
| Permeate TDS or conductivity | Rising salt passage points to membrane damage or scaling |
| Recovery % | Running above the design recovery risks scaling |
| Pre-treatment: chlorine, pH, SDI or turbidity | Chlorine damages membranes, and particles foul them |
| Antiscalant dosing rate and tank level | Under-dosing allows scale |
A commonly used trigger from membrane makers is to clean when normalised permeate flow drops by about 10 percent, salt passage rises by about 5 to 10 percent, or the pressure drop rises by about 15 percent from the reference. Always follow the datasheet of your own membrane. Cleaning early is easier and safer than cleaning late.
Flush the system before a short stop. For long stops, preserve the membranes as your membrane maker advises. Membrane life is often three to five years but depends heavily on feed water and care.
Written by the Arukal Instruments team. Every plant and water source is different, so test your own water and ask us before you buy.
When the pressure drop across the housing rises or at the supplier's interval, whichever comes first. Dirty source water needs more frequent changes.
Look for a fall in normalised permeate flow, a rise in permeate TDS, or a rise in pressure drop across the stages compared with the start-up values.
Yes. Logging the same readings automatically makes drift visible early. See our Remote Monitoring Service.