📞 +91-8538070869✉ info@arukalinstruments.in
Sales & service: West Bengal • Guwahati, Assam
Home / Products / Instruments / Online pH Meter
Online pH Meter
Instruments

Online pH Meter

Continuous pH monitoring and control for water lines

Continuous pH with temperature compensation and 4-20 mA output. Select, supply and support from Arukal Instruments, serving India and Nepal.

0 - 14 pHRange
4 - 20 mAOutput
Relay outputsControl
Automatic temperatureCompensation
Overview

What it does

An online pH meter measures the acidity or alkalinity of water all the time and shows it on a panel display. It can switch a relay or send a 4 - 20 mA signal to a controller, so pH can be watched and corrected without taking samples.

Arukal supplies online pH meters with the electrode, a flow or immersion holder and calibration solutions, and helps you choose the right set-up for your line.

Online pH Meter
1

Sample reaches the electrode

Water flows past the pH electrode in a flow cell or an immersion holder.

2

Signal is measured

The meter reads the electrode and the temperature sensor.

3

Reading is shown

pH is displayed with automatic temperature compensation.

4

Output and control

Relays and a 4 - 20 mA output drive dosing pumps, alarms or a PLC.

Features & benefits

Why choose Arukal Online pH Meter

Continuous reading

Live pH without sampling by hand.

Temperature compensation

Automatic compensation for steady readings.

Control outputs

Relays for dosing and alarms.

4 - 20 mA output

Connects to a PLC, recorder or SCADA.

Easy calibration

Calibrate with standard buffer solutions.

Panel or wall mounting

Fits a plant panel or a wall.

Specifications

Technical specifications

Typical values for guidance. Exact ranges and outputs depend on the model supplied. Please confirm before ordering.

Measuring range
0 - 14 pH
Resolution
0.01 pH
Accuracy
±0.02 pH
Temperature compensation
Automatic, 0 - 100 °C
Outputs
4 - 20 mA, relay contacts
Power supply
230 V AC, 50 Hz
Display
Digital
Mounting
Panel or wall
Electrode
Industrial pH electrode with flow or immersion holder
Applications

Where it is used

RO and DM plants
Boiler and cooling water
Effluent and sewage treatment
Neutralisation tanks
Swimming pools
Food and beverage
Selection guide

What we need to recommend the right meter

  • Water type and line size
  • pH range expected
  • Process temperature and pressure
  • Output needed (relay, 4 - 20 mA)
  • Flow cell or immersion mounting
Range
0 - 14 pH
Output
4 - 20 mA
Control
Relay outputs
Compensation
Automatic temperature
Handling & care

Installation, use and care

  1. 1

    Install

    Fit the electrode where the sample flows steadily and the tip stays wet.

  2. 2

    Calibrate

    Calibrate with buffer solutions on a regular schedule.

  3. 3

    Clean

    Clean the electrode when readings turn slow or drift.

  4. 4

    Replace

    Replace the electrode when calibration no longer holds.

Downloads

Data sheet and brochure

FAQ

Frequently asked questions

How often should I calibrate?

Check often at first, then at a regular interval that suits your water. Calibrate with standard buffer solutions.

Can it control a dosing pump?

Yes. A relay can start the pump, or a 4 - 20 mA signal can drive a controller.

Does it correct for temperature?

Yes. It compensates automatically.

Do you supply electrodes and buffers?

Yes.

Instruments

More online instruments

Need help choosing the right water treatment solution?

Request a Quote →